52
③ Press the right mouse button. Upon pressing the
button, the output port setting dialogue window
appears. Select the output port signal for setting.
Output port setting : User can set an output port.
OFF : Port signal is turned off.
ON : Port signal is turned on.
Set the head up function for SPS/C-SERIES.
No
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
Output port
OP4.0
OP4.1
OP4.2
OP4.3
OP4.4
OP4.5
OP4.6
OP4.7
OP5.0
OP5.1
OP5.2
OP5.3
OP5.4
OP5.5
OP5.6
OP6.0
OP6.1
OP6.2
OP6.3
OP6.4
OP6.5
OP6.6
OP6.7
Description
Presser Foot[PF]
Feeding Frame[FF]
Thread Trimming[TT]
Thread Hold[TH]
Wiper Solenoid
Feeding Frame Left
Twostage Solenoid
Reverse Device Solenoid
Rear Feeding Frame[For 5050]
Tension Release[For 5050]
Pneumatic Output +24V
Oil Control[For 5050]
Head Up/Down[For 5050]
Pneumatic Output +24V
Pneumatic Output +24V
Output +5V
Output +5V
Output +5V
Output +5V
Output +5V
Output +5V
Output +5V
Output +5V
The output port table above is applicable when the C-SERIES I/O
board is used. However, in the existing A/B-SERIES, OP6.0~OP6.7
cannot be used.