27
Funcon
The Sunwind combuson toilet is designed to combust faeces/urine and paper. Do not dispose of
any other items in the toilet. A bag must be inserted prior to each visit. The bag ensures that the waste
is sent directly into the combuson chamber, and that good hygiene is maintained. Inserng the bag
correctly will also minimise the cleaning required.
The combuson is powered by a 2000W heater located above the combuson chamber. This heang
element is thermostacally controlled, and the temperature within the chamber will be approximately
560°C during combuson - each of which lasts for about 75 minutes. Aer combuson, the heater will
be switched o, and the cooling fan will run for as long as necessary.
Should a combuson already be ongoing at the me of the next visit, this combuson will halt, and the
me required for the new combuson will be added to remainder of the previous combuson me.
NOTE!
Aer visits producing minimum amounts of waste, especially when the toilet is used by small
children, it may be necessary to pour a small amount of water into the bag, or help the bag slide
down towards the combuson chamber once this opens.
The waste will disappear into the combuson chamber automacally, with the aid of gravity, once
you iniate a combuson by pressing the buon on top of the toilet.
Venlaon
The toilet must have a permanent venlaon through 110 mm Ø smooth pipes. Use of corrugated
pipes will void the warranty. We recommend using a separate venlaon kit (accessory).
The package contains:
A toilet, a packet of toilet bags, water bole, a bag of screws for installaon of the toilet, instrucons
on how to secure the toilet to the wall, and a user’s manual. Please ensure that the box has not
suered any damage during transport. Should the box be damaged, please contact the carrier or
dealer as soon as possible. The warranty does not cover shipping damage.
NOTE!
The toilet room must not have any other form of mechanical exhaust if air for the toilet is not
taken from outside. If you choose to draw combuson air from the room the toilet is in, it must be
equipped with at least one fresh air valve! Best combuson and air circulaon is obtained if the valve
is located close to and at the same height as the toilet. The venlaon opening must be at least the
same diameter as the air outlet (Ø 110 mm).