TROUBLESHOOTING GUIDE
For technical assistance, please call 1-800-780-4324 x 20311
TECHNOLOGY RESEARCH, LLC A Southwire Company
5250 140th Avenue North ▪ Clearwater, Florida 33760
506-00019A
ERROR MESSAGE DESCRIPTION
REPLACE
SURGE
Surge Expended The Surge Guard built-in surge protection has
been sacriced to protect your equipment and is no longer functioning
properly. The unit is recommended to be replaced.
OPEN
GROUND
Open Ground Disconnect unit. Use a voltmeter to check the
ground and neutral. Voltage should read -0-. If not, nding another
power source is recommended.
REVERSE
POLARITY
Any Line Wired to Neutral Use a voltmeter to check for voltage
on ground or neutral. Voltage should read -0-. If not, nding another
power source is recommended.
L1 High
118V 42A
High Voltage Voltage is over recommended operation, check with
power source to lower voltage to >132V.
L1 Low
118V 42A
Low Voltage Voltage is under recommended operation, check with
power source to raise voltage to <102V.
CUR
HIGH
Current High Current exceeds the recommended operation.
Check connection with voltmeter and verify voltages are within normal
operation. If not, it is recommended to nd another power source.
PLUG
OVERHEAT
Over-Temperature Temperature exceeds the recommended oper-
ation. Check connection with voltmeter and verify voltages are within
normal operation. If temperature exceeds, disconnect unit, allow to
cool completely and recommend to nd another power source.
Model 34830
30A Portable Surge Guard
®
with LCD Display
TROUBLESHOOTING ERROR CODES
Questions or concerns? Call our technical support department at 800-780-4324 x 20311