Sutron Corporation 8310 & 7310 Users Manual 8800-1125Rev. 2.7 (BETA) 4/16/2014 pg. 174
ResetCount
YES
FilterValue
3 (see Counter measurement type in
Chapter 4)
SwitchedPwr
None
Processing
Slope-Offset
Slope
Slope of sensor, inches or mm water per
tip
Offset
0
Cal Slope
1
Cal Offset
0
Daily Setup
Field
Value
MeasName
DAYRAIN
Measurement Type
Accumulate
Measurement
Interval
24:00:00
Measurement Time
00:00:00
SampleInterval
01:00:00
InputType
Reference
Reference
Mx:O1: HRRAIN
SwitchedPwr
None
Processing
NONE
Cal Slope
1
Cal Offset
0
Pressure Transducer
A pressure transducer operates identical to the load cell, described previously.