Do you have a question about the Svedbergs 54070 and is the answer not in the manual?
Use key no. 24 for tightening. Do not install heater with control panel attached to heating element.
Fit cartridge to base, use thread tape to prevent leakage. Element fits lower connections only.
Connect to power only after filling. Connecting without water damages the element. Contact electrician for fixed installation.
Align locating pin (A) with groove (B) and push control panel firmly onto heating element.
Turn panel up to 340° to face forward. Do not force if resistance is met, as damage may occur.
Tighten the grab screw with the allen key for long-term reliability of the control box.
Fill slowly to avoid air pockets. Use water or water/antifreeze mix. Check fluid level after one hour.
Press the On/Off button to start or stop the electric element. Power is cut only when plug is removed.
Set hour and minute using arrow buttons and confirm settings. Clock is then activated.
Use arrow buttons to set desired temperature. Heat indicator shows when temperature is reached.
Element automatically activates if temperature drops to 6°C to prevent freezing. Display shows 'AF'.
Dries towels at 50°C for a set time. Time can be extended by 30 min increments up to 4 hours.
Set up to four time intervals (T1-T4) for individual heating schedules. Timer controls element 24/7 when active.
Configure start times and temperatures for up to four intervals (T1-T4) using arrow buttons and confirmation.
Diagnose issues like no display, overheating, or no heat using the fault finding table.