S5
S6
Display
Message
Description
Selection
H-dl
T-OF
H-OF
SETT
HY-T
SETH
HY-H
PASS
T-AC
T-DL
H-AC
SetValueforthe Temperature
SetValueforthe Hysteresis
Hysteresisvalue- Temperature
Hysteresisvalue-Humidity
SetPassword
Temperature Action
Humiditycompressoroff
timeinterval(delaytime)
Humidity Action(increaseor
decreaserelativehumidity)
100.0(-50.0to400.0)
2.0(0.1to9.9)
20(000or00.0)
2(1to9)
25
Heat/Cool
00(0-999)minutes
0000(0-999)minutes
-30.0to30.0°C
-30.0to30.0°C
Temperatureoffset
RHoffset
Note:
Heat/Cool(Touserelayaction
forheatingorcoolingpurpose)
TEMP.RANGE:
RHRANGE:
0-400°CPIDON/OFF
100%PIDON/OFF
18
19
11
12
13
14
15
16
17
20
30
I/PGND
PT-100
TEMP
RH
+5V
RED
GREENBLACK
ParameterDescription
ConnectionDiagram
TEMP.SENSOR: RTD
MODEL NO.: DTC-9621-1
RHSENSOR: 3.3VDC
L
~
N
89
12
3
4
5
6
7
10
!!
HEATER
RH
230V AC
NO NONC NCC C
Temperaturecompressoroff
timeinterval(delaytime)
0000
000
T-OF
H-OF
SET
Presskey
Presskey3SecondforPIDtunning
Use&key
Use&key
HY
0020
0400
0100
0004
PID
Mode
KPH
KIH
KDH
CTH
Mode
ControlModeHumidity
IfselectPIDMode
Continuewith1stpage..................
SET
Presskey
SET
Presskey
SET
Presskey
SET
Presskey
SET
Presskey
Use&key
Use&key
Use&key
(Use&key)
Use&key
Heat
Cool
H-AC
H-AC
0000
H-DL
SET
Presskey
Use&keytoselect
(RH/DRH)
Humidity Action
O/P-2
(HY /PID)
KPH
KIH
KDH
CTH
Mode
KPT
Kit
Kdt
CTT
Proportionalparameterfor
Temperature
Proportionalparameterfor
Humidity
Integralparameterfor
Temperature
Integralparameterfor
Humidity
Cycletimerfor Temperature
Cycletimerfor Humidity
Derivativeparameterfor
Temperature
Derivativeparameterfor
Humidity
MethodisHysteresisorPropo-
rtionalModetocontrolHumidity
On-off(Hy)/PID
20
20
400
400
100
100
2(2-60)seconds
2(2-60)seconds
Mode
MethodisHysteresisorPropo-
rtionalModetocontrol Temp.
On-off(Hy)/PID
ENT
Presskeytosave&exitfromanyparameter
(TemperatureOffset)
(HumidityOffset)

Other manuals for SWASTIK DTC-9621-1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SWASTIK DTC-9621-1 and is the answer not in the manual?

SWASTIK DTC-9621-1 Specifications

General IconGeneral
BrandSWASTIK
ModelDTC-9621-1
CategoryController
LanguageEnglish