Electrical Systems
39
Fault
3.4 FAULT TABLE
Possible Cause Proposed Fix
No 240 volt output
No 12 volt output
Connecting lead between the site and Leisure Vehicle
not connected
RCD switched off
RCD not operating correctly
MCB switched off
No or deficient supply from site
Other fault
No 240v supply
Charger not switched on
Battery not connected and / or charged
Power switch on control panel not switched to ON
Battery flat / Battery fuse blown
Fuse blown
Check and connect lead as per 3.2.C
Check also input connector at the base of the PSU
2007
Reset RCD as per 3.2.D
Check supply polarity; if the RCD continues to fail
contact your Dealer, as there is probably a wiring or
equipment fault.
Reset MCB by switching OFF (down position) then
back ON (up position), if the MCB continues to fail
contact your Dealer, as there is probably a wiring or
equipment fault.
Contact site Warden for assistance
Contact your Dealer
Check all above
Switch charger switch on (I) position, switch will
illuminate
Install charged battery as per 3.3.B
Turn power on at control panel
Recharge battery, check fuses, check charging voltage
is present at battery
Check all fuses are intact and the correct value fuse is
installed as per fuse table shown in 3.5