10. AC Generator / Starting Clutch
10-4
AC Generator Removal
Remove 2 mounting screws from CPS.
Remove 3 screws from right crankcase cover and
then remove generator coil set.
Right Cover Bearing
Rotate the bearing by fingers to check if the
bearing rotation is smooth and silent.
Check if the bearing outer parts are closed and
fixed, replace it if necessary.
Remove the bearing 6201 with inner bearing
puller.
Special tool:
Inner bearing puller SYM-6204025
Install the bearing 6201 bearing with special tool.
Special tool:
Right crankcase cover bearing 6201 presser
SYM-9614000-HMA RB1 6201
To this chapter contents
CPS screws
Cir clip
3 screws
Inner bearing puller
Inner bearing presser