12. Cooling System
12-6
Check reserve tank
Open the inner box lid.
Check the coolant level in the reserve tank.
Add coolant to proper level if too low.
Caution
Do not make the coolant level in the reserve
tank too high.
Radiator
Check
Check for any leakage from weld seam.
Blow radiator clean using compressed air. If the
radiator is blocked by dirt, use low pressure water
jet to clean it.
Care shall be taken when straightening the sink
fan.
Remove
Place a water pan under the water pump; loosen
the drain bolt to drain out the coolant.
Remove the front cover and under spoiler (refer
chapter 12).
Loosen the radiator mounting bolts (4 bolts).
Each side 2 bolts
Viewing window
Drain bolt