10. AC. Generator / Start Clutch
10-2
Precautions in Operation
General information
y Refer to chapter 17: The troubleshooting and inspection of alternator.
y Refer to chapter 17: The service procedures and precaution items of starter motor.
Specification
Item Standard value (mm) Limit (mm)
ID of starting clutch gear 25.026~25.045 25.050
OD of starting clutch gear 42.192~42.208 42.100
Torque value
Flywheel nut 5.0~6.0kgf-m
Starting clutch hexagon bolt 1.0~1.4kgf-m with adhesive
8 mm bolts 0.8~1.2kgf-m
12 mm bolts 1.8~2.2kgf-m
Special tools
AC.G. flywheel puller SYM-3110000-HMA
Left crank case cover 6201 bearing puller SYM-9614000-HMA RB1 6201
Inner bearing puller SYM-6204022
Universal holder SYM-2210100