EasyManua.ls Logo

SyQuest SQ555 - User Manual

Default Icon
114 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Question and Answer IconNeed help?

Do you have a question about the SyQuest SQ555 and is the answer not in the manual?

Summary

SECTION 1 SQ555-Installation

1.1 WHAT YOU NEED TO INSTALL THE SQ555

Lists essential components and prerequisites for installation.

1.2 INSTALLING THE DISK DRIVE

Details the physical installation process for the disk drive into a computer.

1.3 PREPARING A CARTRIDGE FOR USE

Explains the necessary steps to prepare a cartridge before its first use.

SECTION 2 SQ555-Operation Guide

2.1 BEFORE YOU BEGIN

Provides initial considerations and warnings before operating the SQ555.

2.2 HANDLING INSTRUCTIONS

Outlines essential guidelines for safely handling and operating the SQ555 drive.

2.3 OPERATING SYSTEM SOFTWARE

Briefly mentions the compatibility with operating system software.

2.4 INSERTING AND REMOVING THE SQ400 DISK CARTRIDGE

Describes the procedure for inserting and removing the disk cartridge.

SECTION 3 SQ555-Functional Characteristics;Overview

3.1 GENERAL OPERATION

Provides a general overview of the SQ555's operational capabilities.

3.2 FUNCTIONAL OVERVIEW

Details the internal functional blocks and data flow of the SQ555.

3.3 SCSI CONTROLLER

Explains the role and functions of the SCSI controller.

SECTION 4 SQ555-SQ400 Disk Cartridge

4.1 OVERVIEW

Introduces the SQ400 disk cartridge and its structure.

4.2 DISK INFORMATION PATTERNS

Describes the patterns used for disk information, including servo and data records.

4.3 TRACK ASSIGNMENT

Details how tracks are assigned and formatted on the cartridge.

SECTION 5 SQ555-Diagnostics

5.1 OVERVIEW

Introduces the diagnostic capabilities of the SQ555.

5.1.1 Power-Up Test

Describes the power-up diagnostic test sequence.

5.1.2 Performance Diagnostic Tests

Details the various performance diagnostic tests available.

SECTION 6 SQ555-SCSI Implementation

6.1 OVERVIEW

Provides an overview of the SQ555's SCSI compliance and bus architecture.

6.2 SQ555 ANSI COMMANDS DESCRIPTION

Details the ANSI SCSI commands supported by the SQ555.

6.2.1 Test Unit Ready Command Operation Code: 00 H

Explains the 'Test Unit Ready' command and its operation code.

6.2.2 Rezere Unit Command Operation Code: 01 H

Details the 'Rezere Unit Command' and its operation code.

6.2.3 Request Sense Command Operation Code: 03 H

Details the 'Request Sense Command' and its operation code.

6.2.3.1 Non-Extended Sense

Describes the format for non-extended sense data.

6.2.3.2 Extended Sense

Describes the format for extended sense data.

6.2.4 Format Command Operation Code: 04 H

Explains the 'Format Command' and its operation code.

6.2.4.1 Format Unit Command Variations

Details variations and parameters for the Format Unit command.

6.2.4.2 Defect List - Block Format

Describes the defect list format for block formatting.

6.2.4.3 Defect List - Block Format When Using Manufacturing Defect List

Details the defect list format for manufacturing defect lists.

6.2.4.4 Defect List - Physical Sector Format

Explains the defect list format for physical sector formatting.

6.2.5 Reassign Blocks Command Operation Code: 07 H

Details the 'Reassign Blocks Command' and its operation code.

6.2.6 Read Command Operation Code: 08 H

Explains the 'Read Command' and its operation code.

6.2.7 Write Command Operation Code: 0 AH

Details the 'Write Command' and its operation code.

6.2.8 Seek Command Operation Code: 0 BH

Explains the 'Seek Command' and its operation code.

6.2.9 Read Usage Counters Command Operation Code: 11 H

Details the command to read usage counters.

6.2.10 Inquiry Command Operation Code: 12 H

Explains the 'Inquiry Command' and its operation code.

6.2.10-1. Inquiry Data

Describes the data returned by the Inquiry command.

6.2.11 Mode Select Command Operation Code: 15 H

Details the 'Mode Select Command' and its operation code.

6.2.11-1. Mode Select Header

Explains the header structure for the Mode Select command.

6.2.11-2. Page Codes

Lists and describes the page codes used in mode selection.

6.2.11-3. Operating Parameters

Describes the operating parameters page.

6.2.11-4. Error Recovery Parameters

Details the error recovery parameters.

6.2.11-5. Table Summary All Valid Modes of Operation

Summarizes all valid modes of operation for the drive.

6.2.11-6. DMA Parameters

Explains the DMA parameters.

6.2.11-7. Format Parameters (Default Only)

Describes the default format parameters.

6.2.11-8. Geometry Parameters (Default Only)

Details the default geometry parameters.

6.2.11-9. Vendor;Product Identification

Explains how vendor and product information is identified.

6.2.14 Mode Sense Command Operation Code: 1 AH

Details the 'Mode Sense Command' and its operation code.

6.2.14-1. Page Codes

Lists and describes page codes for the Mode Sense command.

6.2.15 Start;Stop Command Operation Code: 1 BH

Explains the 'Start/Stop Command' and its operation code.

6.2.16 Receive Diagnostic Results Command Operation Code: 1 CH

Details the command to receive diagnostic results.

6.2.17 Send Diagnostic Command Operation Code: 1 DH

Explains the 'Send Diagnostic Command' and its operation code.

6.2.19 Read Capacity Command Operation Code: 25 H

Details the 'Read Capacity Command' and its operation code.

6.2.19-1. Read Capacity Data

Describes the data returned by the Read Capacity command.

6.2.20 Extended Read Command Operation Code: 28 H

Explains the 'Extended Read Command' and its operation code.

6.2.21 Extended Write Command Operation Code: 2 AH

Details the 'Extended Write Command' and its operation code.

6.2.22 Extended Seek Command Operation Code: 2 BH

Explains the 'Extended Seek Command' and its operation code.

6.2.23 Verify Command Operation Code: 2 FH

Details the 'Verify Command' and its operation code.

6.2.24 Read Defect Data Command Operation Code: 37 H

Explains the 'Read Defect Data Command' and its operation code.

6.2.25 Write Buffer Command Operation Code: 3 BH

Details the 'Write Buffer Command' and its operation code.

6.2.26 Read Buffer Command Operation Code: 3 CH

Explains the 'Read Buffer Command' and its operation code.

6.2.26-1. Read Buffer Header

Describes the header structure for read buffer data.

6.2.26-2. Read Buffer Descriptor

Explains the buffer descriptor format for read buffer commands.

6.3 SENSE KEY AND ERROR CODE DESCRIPTORS

6.3.1 Sense Keys

Lists and explains the sense keys used for error reporting.

6.3.2 Additional Sense Codes

Details additional sense codes for error reporting.

SECTION 7 SQ555-Maintenance

7.1 CLEANING REQUIREMENT

Specifies when and how the spindle motor hub requires cleaning.

7.2 CLEANING EQUIPMENT

Lists the necessary equipment for cleaning the drive.

7.3 CLEANING PROCEDURE

Provides the step-by-step procedure for cleaning the drive.

APPENDIX A TECHNICAL SPECIFICATIONS

Unformatted Capacity

Details unformatted storage specifications of the SQ555 disk drive.

Formatted Capacity

Lists the formatted storage specifications of the SQ555 disk drive.

Interface

Describes the interface standards used by the SQ555.

Seek Time

Specifies the typical seek times for the SQ555 drive.

Latency Time

Details the average latency time for the SQ555 drive.

Data Transfer Rate

Outlines the internal and external data transfer rates.

Flaw Handling (Sector Sparing)

Explains methods for handling disk flaws and sector sparing.

Seek Error Rate

Defines the seek error rate specification.

Disc Speed

Specifies the rotational speed of the SQ555 drive.

Recording Density

Details the recording density characteristics.

Power Supply Ratings

Lists the voltage and current ratings for power supply.

Acoustical Noise

Specifies the acoustical noise level of the drive.

Safety

Lists safety certifications and compliance standards.

Physical Characteristics

Provides physical dimensions and weight of the drive and cartridge.

Reliability and Maintenance

Details mean time between failures and service life objectives.

APPENDIX B ENVIRONMENTAL REQUIREMENTS

Temperature

Specifies operating and non-operating temperature ranges.

Relative Humidity*

Details operating and non-operating relative humidity levels.

Altitude

Lists operating and non-operating altitude limits.

Shock (on mounting frame and front panel)

Describes shock resistance specifications.

Drive and Cartridge

Specifies shock and vibration resistance for drive and cartridge.

Vibration (sweep rate of 1 octave;min.)

Details vibration specifications for operating and non-operating states.

EMI Susceptibility

Specifies EMI susceptibility levels.

Electro Static Discharge

Outlines ESD performance requirements.

APPENDIX D SCSI ELECTRICAL SPECIFICATION

D.1 SCSI BUS SIGNALS

Describes the signals on the SCSI bus and their pin assignments.

D.1.2 Signal Characteristics

Details the characteristics of SCSI bus signals.

D.2 SCSI SIGNAL SOURCES

Identifies the sources for SCSI bus signals.

D.3 SCSI BUS TIMING

Explains the timing specifications for SCSI bus operations.

D.3.1 Arbitration Delay

Details the arbitration delay timing.

D.3.2 Assertion Period

Specifies the assertion period for SCSI signals.

D.3.3 Bus Clear Delay

Specifies the delay for clearing the SCSI bus.

D.3.4 Bus Free Delay

Details the delay required for the bus to become free.

D.3.5 Bus Set Delay

Explains the delay for setting the bus.

D.3.6 Bus Settle Delay

Specifies the delay for settling the bus after signal changes.

SyQuest SQ555 Specifications

General IconGeneral
Capacity44 MB
InterfaceSCSI
Form Factor5.25-inch
Data Transfer Rate1.25 MB/s
Rotational Speed3600 RPM