System Cleaners low-pressure systems may only be used in conjunction with soaps and chemicals that are approved
for cleaning within the food or transport industries.
Soaps and chemicals that are classified as highly corrosive, toxic or which pose a health risk to humans or animals
may not be used.
The system must not be used together with solvents or volatile liquids that pose a health risk or are inflammable.
In the event that the system is used with non-approved soaps, chemicals or solvents, System Cleaners A/S disclaims
all liability.
If in doubt, please contact your soap or chemical supplier and read the supplier manual.
In the event that you use the system with chemicals that require mandatory labelling, or if the water temperature
exceeds 50°C, a low-pressure gun with an automatic closing device must be used.
Start
The system starts automatically in the event of falling pressure in the outlet pipe like when the operator opens the low
pressure gun or valve.
Stop
The system stops automatically shortly after water is no longer being used like when the operator closes the low
pressure gun or valve.
Leaks
If there are leaks in the system’s non-return valve, pipelines or satellites, the pump will start although there is no
water being used.
Pressure relief
After use shut the isolating valves over the equipment and relieve air and water pressure in hoses etc.
MAINTENANCE
Water filter
Depending on the mains water quality it may be necessary to clean the water filter on a regular basis to prevent the
pump from stopping.
Flow switch
The flow switch does not require maintenance.
Water non-return valve
Water non-return valves are critical wear parts and should be replaced yearly.
Compressor
The compressor is oil-less and does not require lubrication or any other maintenance.
Air filter
Depending on the quality of the compressed air it may be necessary to empty condensation collected in the air filter
bowl on a regular basis.
Injector system
The injector system consists of foot strainer, dosing valve, non-return valve and injector.
Chemical residues compromises the function of the injector and flushing with warm water after each use is required to
maintain trouble free operation.
Depending on the water quality it may be necessary to de-scale the water side of the injector on a regular basis
following the chemical supplier’s guidelines.