Multi-Function LED and Troubleshooting:
This troubleshooting table is intended as a helpful guide and is not all inclusive. There could be other causes and solutions for a
non-functioning product.
4 7/8
2 1/8
3 1/2
4 3/8
7/8
3 1/8
1 9/16
LED STATUS
POWER
LED STATUS
BATTERY ONLY
INDICATES POSSIBLE CAUSE POSSIBLE SOLUTION Audible Alarm
Solid Green ----------- Normal
----------- 1 Green Blink
every 10 Seconds
(Approximately)
Normal ----------- ----------- -----------
Solid Green with
one red blink
----------- Low Batteries Low Batteries Replace batteries Chirp every 60 second
Batteries installed incorrectly Install batteries correctly Chirp every 60 second
Not illuminated ----------- Power off Power supply not plugged in Plug in power supply -----------
------------ Not illuminated Power off Batteries installed incorrectly
or not at all
Install batteries correctly/
install batteries
-----------
In between cycles Normal Wait 15 seconds for indication
blinks
Solid Red with 2
red blinks
Solid dim Red with
2 red blinks
Sensor error Bad wire connection
Make sure wiring connections
are solid and tight and the
quick connect is all the way in
Chirp every 60
seconds
Make sure sensors wired per
instructions
Chirp every 60
seconds
Solid Red with 3
red blinks
Solid Dim Red with
3 red blinks
Valve error Valve is not connected to the
control
Connect the valve to the con-
trol
Chirp every 60
seconds
Bad wire connection Make sure wiring connections
are solid and tight and the
quick connect is all the way in
Chirp every 60
seconds
Solid Red with 3
red blinks
----------- AC power error Wrong power supply Use power supply provided Chirp every 60
seconds
Continuous Red
blinks
Continuous Red
blinks
LeakBreaker has
Triggered
Sensor has detected water Determine the water source
and correct. Dry the sensor
and reset the LeakBreaker.
Press the open button to reset.
Constant alarm.
Press the mute button
to silence the alarm.
Solid Red Solid Red
LeakBreaker
®
has trig-
gered and the water on
the sensor has dried up
Sensor has detected water Determine the water source
and correct. Press the open to
reset.
Constant alarm.
Press the mute button
to silence the alarm.
Dimensions (for reference purposes):