V-10
TROUBLESHOOTINGMACHINE TRAVEL
Inspect the charge pres-
sure.
2
Inspect the pilot valve.1
HST pump fault.5
Repair or replace HST pump
charge relief valve.
Normal
Normal
Pressure low
Inspect the output pres-
sure of the HST pump.
3
Repair or replace HST
pump.
Repair or replace travel mo-
tor.
Travel motor fault.
Repair or replace pilot
valve.
Faulty
Perform replacement
test for the high pres
-
sure relief valves.
4
Repair or replace high pres-
sure relief valve.
Pressure low
Problem solved
No change
TRAVEL TRAIN FAULT.
Normal