V-29
TROUBLESHOOTING
AUXILIARY HYDRAULICS
T9E008E
0.85YR
0.85L
T9E009
Inspect the flow selec-
tor solenoid.
3
Inspect the resistor.2
Inspect the flow selec-
tor switch.
1
Repair or replace the flow
selector solenoid.
Faulty
Replace the resistor.
Faulty
1. Inspect the flow selector switch.
Set the safety bar to the driving position and turn
the proximity switch and the starter switch to the
“ON” position. Push the flow selector switch to
“ON”. If the green lamp lights, the switch is nor
-
mal.
2. Inspect the resistor.
Disconnect the wirings (0.85YR, 0.85L) from
the resistor and check for continuity with a tes
-
ter.