OUTLINE1
PANELDESCRIPTION(HDA300A)
TheHDSeriessensorsdirectlydetectinfraredraysradiatedfroman
objectheatedtoahightemperatureandoutputsignals,andasetof
sensorsiscomposedofanamplifierunitandareceiver.Receivers
comeintwodifferenttypes:cordconnection(directreception)and
fiberoptic(detachable/fixedfiberopticunit)types.Alsothecord
connection(directreception)typeincludeshigh-temperatureandlow-
temperaturedetectiontypes.Theoperationmodecanbeselectable
betweenon-delay,off-delay,one-shotandtimerdisabledwiththe
operationsettingDIPswitch.InadditionaDINstandardrailof35mm
inwidthmaybeusedforsecuringthesocket.
Partnumbersanddetectiontemperature
Cabletype
 ModelHD301A
 ModelHD601N
Fibertype
 ModelHD400
 ModelHD502F
Specifications(Detector)
(Amplifier)
Models
Wiring
Flyinglead20mlength
Flyinglead20m Flyinglead2m
Ambient
temperature
Ambient
humidity
Withstandvoltage
Insulationresistance
Protection
35to85%RH
500VDCmega20MΩmin.
−25to+70℃
−25to+70℃
Fiberunit−20to+200℃
Fiber(+70℃)
1500VACfor1minute
IP66
IP40
CasegroundedCasegrounded
IP66
35to85%RH
 Fiberunit95%RHmax.(70℃min.20%RHmax.)
Fiberoptictype
HD400 HD502F
Model HDA300A
AC100/110V・AC200/220V±10%,50/60Hz
5VAMax.
Relayoutput/Voltageoutput
Relayoutput:1CAC250V5A(Max.)(resistiveload)
Voltageoutput:12VDC5mA(Max.)
Lightreception(fordetectionofheatedmaterial):SelectableON/OFFoperation
Timerselectable
On-delay,Off-delay,One-shotandNonetimerselectable
Relayoutput:25ms,Voltageoutput:3ms
0.1to1s/1to10sselectable
Terminalblock(screwdiameter:3.5mm)
IP20
Powersupply
Currentconsumption
Outputmode
Rating
Operationmode
Timer
Time
Responsetime
Wiring
Protection
Foreasyadjustment,disablethesettingof
thetimermode(NONTIMSw1:ON,Sw2:ON).
①Turnthesensitivityadjustmentvolumeontheamplifierunit(SENS.)
rightallthewaytothemaximumsensitivity(clockwise).
②Adjustthesensitivityinthefollowingcases:
1.Sensoractivatedbytheexternallight.
2.Sensoractivatedsoonerbyreflectionwhenhigh-temperature
detectionobjectapproaches.Sensorstaysactivateddueto
reflectionevenaftertheheatedmaterialhaspassed.
Inanyofthecasesabove,changethelocationofthereceiveror
decreasethesensitivity.Whendecreasingthesensitivity,adjustso

astoachievethelevelindicationof"5"orhigheratthetimeofdetection.
Sensitivityadjustmentvolume
Turningright(clockwise)increasesthesensitivityanddecreases
thedetectiontemperature.
Levelindicator:Providesdigitalindicationofthereceivedlight
intensity.Thepresetoperationlevelisapprox.2.5.
"H"isshownforlevel9orhigher,indicatingsaturation.
LEVEL5:Doubletheoperationlevel
LEVELH:Overquadrupletheoperationlevel.
Powerindicator:Illuminateswhilethepowerissupplied.
Operationindicatoroflightreception:Illuminatesforlightreception
(detection).
Timeradjustmentvolume:Turningright(clockwise)increasesthetime.
SENS.
LEVEL
POWER
OPERATION
TIME
OperationsettingDIPswitch: 
       Usedtosetthetimermode/operationmode.
                (TurntheswitchleftforOFFandrightforON)
               ←Sw1,2:Timeroperationmodesettingismade
                     bythecombinationoftwoswitches.
               
←Sw3:
Selectthetimerrangebetweenupto
                    1sor10s.
               
←Sw4:
Optionswitch.
                    EnsurethatitisalwaysOFFwhenusing.
               ←Sw5:TurnOFFtoinverttheoutputlogic.
(TheoperationDIPswitchsettingsshownaboveindicatethefactorysettings.)
0 0.5m 1m 2m 3m
HD301AAboutφ30mmAboutφ70mm
HD601NAboutφ25mmAboutφ50mm
Aboutφ140mm
Aboutφ100mm
Aboutφ210mm
Aboutφ150mm
HD400fiberopticcablelensunit
HD400fiberopticcable
HD502F
(FA51,52)
About
φ8mm
0 20mm 50mm 100mm 300mm 500mm
About
φ21mm
About
φ43mm
φ17mm
About
φ52mm
About
φ87mm
DETECTIONABILITY2
DETECTIONFIELDOFVIEWCHARACTERISTICS(Typicalexample)
3
SPECIFICATIONS4
5
ADJUSTMENT6
OperationsettingDIPswitch
○ ○ □
○ ○ □
□
□
□
TIMER
OST OFD
TIME
OPTION
LIGHT
10s
OFF
OFF
1s
ON
ON
OND
TIM
NON
●
Thankyouforusingproducts.
Pleasereadthismanualcarefullypriortousethesensor.
Amplifierunit
Optical
receiver
Fiberopticunit
Detectiontemperature
atacoverageratioof
100%(
ε
=0.8Fe)
HD301A
HD601N
HD400
HD502F
GT205(0.5m)
GT21(1m)
GT22(2m)
GT23(3m)
370℃min.
650℃min.
430℃min.
440℃min.
460℃min.
490℃min.
560℃min.
HDA300A
HD301A HD601N
Sens.Down Sens.Up
Question and Answer IconNeed help?

Do you have a question about the Takex HDA300A and is the answer not in the manual?

Takex HDA300A Specifications

General IconGeneral
BrandTakex
ModelHDA300A
CategorySecurity Sensors
LanguageEnglish