page 022
ITEM
ERROR CODES
(MX VERSION)
ERROR CODES
(L1E VERSION)
DESCRIPTION ERROR ANALYSIS SOLUTIONS REMARKS
19 E19 00040
Battery discharge
overheated error.
When the battery
pack is discharging,
the battery pack
inner temperature is
overheated.
Stop to riding the bike
until the discharge
overheat protection
unlocked.
It's strongly suggested to
use the bike as per the
owner's manual.
20 E20 00050
Battery charge
overheated error.
The high battery cell
temperature caused
this error.
Stop to charging
the battery until the
charge overheat
protection unlocked.
It's strongly suggested to
use the bike as per the
owner's manual.
21 E21 00060
Battery discharge low
temperature error.
When the battery
pack discharges in
very low temperature,
the battery will carry
out the protection
function for low
temperature.
Stop to riding
the bike until the
low temperature
protection unlocked.
It's strongly suggested to
use the bike as per the
owner's manual.
22 E22 00070
Battery charge low
temperature error.
When the battery
pack is charged in
very low temperature,
the battery will carry
out the protection
function for low
temperature.
Stop to charging
the battery until the
low temperature
protection unlocked.
It's strongly suggested to
use the bike as per the
owner's manual.
23 E23 00080
Battery discharge,
MOS overheated
error.
It's caused by the
overheated MOS
when the battery
pack is discharging.
Stop to riding the bike
until the overheat
protection unlocked.
It's strongly suggested to
use the bike as per the
owner's manual.
24 E24 00090
Battery charge, MOS
overheated error.
It's caused by the
overheated MOS
when the battery
pack is charging.
Stop to charging
the battery until the
discharge overheat
protection unlocked.
It's strongly suggested to
use the bike as per the
owner's manual.
25 E25 000A0
Soft-start circuit
overheated error.
If the temperature
is high when use
the soft-start, will
cause the discharge
MOS not work,
and lead the entire
soft-start circuit to be
overheated.
Stop to riding the bike
until the overheat
protection unlocked.
26 E26 000B0 Storage error.
It's caused by the
faulty operation
during the production.
Send the bike to the
nearest dealer to
repair.
27 E27 000C0
Discharge fuse
failure error.
Don't have this error
for STING's battery.
Just a default setting
error.
28 E28 000D0
Charge fuse
failure error.
Don't have this error
for STING's battery.
Just a default setting
error.