EasyManua.ls Logo

Tattile Vega1 Series - Removing a PIN Connection from the Power Supply Cable; Figure 13: Correct Backshell Mounting

Tattile Vega1 Series
38 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4PreparationandInstallation
RMM_00053_02 25 / 38 VEGA1 Series
6. Passthecabletroughttheadapter
7. InsertthePINsintothecorrectholesoftheconnector:
A:GND
B:GND
C:+24Vdc
D:+24Vdc
M:Earth/ground
8. TightenadapterwithplugUTS6orreceptacleUTS1
9. Tightenthenuttorearof
eitherUTS1orUTS6
(recommendedtorquevaluestobeappliedaccordingprevioustable)
NOTICE!Improperuse!
RiskoflossIPprotectiondegreeandwaterinfiltration.
Insertonly“one”cableintheNutoftheConnector.
Ifmultipleconnectionsarerequired,useanexternaljunctionbox,becauseonlyonecablemust
beinsertedintotheconnector.

Figure13: CorrectBackshellMounting
Importantadvices.
ThejunctionboxandthecablethatconnectstheremotecameramustmaintaintheIPdegree
ofprotectionthatpreventstheentryofwater.
ItisalsorecommendedtofixthejunctionboxatalowerheightoftheCameratoprevent
waterfrompouringintothecable.
Theconnectorcableisreadyforuse.
4.4.2 Removing a PIN Connection from the Power Supply Cable
ThischaptershowshowtoeasilyremoveaPINconnectionfromthepowersupplycable.Theprocedure
isusefultomodifythecablingincaseoferrors.
Thefollowinginstrumentationisrequired:
SOURIAUMWRX20D44 extractiontool.

Table of Contents