EasyManua.ls Logo

Taurus TAS-3000 - Technical Specifications and Data; Model Specifications; Ambient Temperature Operating Range

Taurus TAS-3000
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Tech specification and data
Model TAS-2250 TAS-3000 TAS-4500 TAS-6000
Funcion Cool & warm type
Type of climate T1
Refrigeration volume (BTU) 9000 12000 18000 24000
Heating volume(BTU) 10000 13000 19000 26000
Imput power cooling 960 1412 2110 2730
heating 1035 1325 2190 2580
Standard current cooling 4,3 6,1 9,5 12,4
heating 4,6 5,8 9,9 11,7
Drying volume (L/h) 1,3 1,5 2 3
Circulation wind volume(m/h) 470 540 780 1180
Noise dB(A) indoor unit <38 <40 <47 <54
Outdoor unit <50 <50 <54 <60
Refrigerant number R407C
Mass (Kg) 0.73 0.85 1.70 2.0
IP code(outdoor unit) IP24
Power supply Single phase 220-230V-/50Hz
Weight(kg) Indoor unit 9 11 15 18
Outdoor unit 29 33 53 58
dimension (mm) Indoor unit 790x265x175 885x290x185 1100x335x215 1140x325x190
(lengthXwindthXheight) Outdoor unit 765x260x530 765x260x530 800x300x680 845x300x680
Ambient Temperature
Cooling Indoor Maximum DB/WB: 32º/23º C
Minimum DB/WB: 18º/14º C
Outdoor Maximum DB/WB: 43º/26º C
Minimum DB/WB: 18º
Heating Indoor Maximum DB/WB: 27º
Minimum DB/WB: 15º
Outdoor Maximum DB/WB: 24º/18º C
Minimum DB/WB: -7º/-8º C

Other manuals for Taurus TAS-3000