Tools
Problem Likely caused by Action required
EasySqueeze arms do not move
Any faults of main unit. Check if main unit is working properly.
Overload protection is activated.
Release pressure from ES arms, make sure lifted object is
in secure position before releasing pressure.
Actuators are damaged.
Replace actuators.*
No electrical connection in slip
ring.
Check connection in slip ring, replace if needed.*
No signal from control panel.
Check signal from control panel to circuit board.*
Mother board is damaged.
Replace mother board.*
Control board is damaged.
Replace control panel.*
Circuit board for squeeze function
damaged.
Replace circuit board.*
EasyTurn does not turn
Any faults of main unit. Check if main unit is working properly.
Overload protection is activated.
Place center of gravity of load in rotation center.
Turn motor is damaged.
Replace turn motor.*
No signal from control panel.
Check signal from control panel to circuit board.*
Mother board is damaged.
Replace mother board.*
Control board is damaged.
Replace control panel.*
Circuit board for turn function is
damaged.
Replace circuit board.*
EasyTurn does
not stop at pre-
dened angle
Angle sensor broken. Replace angle sensor.*
No signal from control panel.
Check signal from control panel to circuit board.*
Circuit board for turn function is
damaged.
Replace circuit board.*