3. Normal Operation at Start-up
Every time that power is switched on to your Taylex ABS Control Panel, the display (B) will
count down from 9 to 1. The audible alarm will sound in unison with the numeric progression.
This is a TEST MODE, at the completion of which, the display will show a 0 rotating to
indicate that the system has tested out correctly. Unless a visual or audible alarm occurs, this
is the normal operating display.
4. Low Occupancy
Mode.
This function should NOT be accessed by the Home Owner. If it is required, it will be
activated by your Service Agent. Incorrect use of this mode may result in poorly treated water
being discharged into the environment possibly causing degradation of your land and
becoming a health hazard to you, you family, friends and neighbours.
5. Alarm Recognition and Rectification.
Visual Alarms - Strobe Light (E) and Display (B )
All faults are indicted by the numbers appearing in the display (B) and by the corresponding
number of flashes of the strobe light (E). If two faults occur simultaneously, then two numbers
will be displayed in sequence, the strobe will mimic these numbers and after a short interval,
the display and alarm will repeat the sequence.
Audible Alarm and how to Silence it.
The audible alarm mimics the number of flashes of the Strobe light and the visual display. To
silence the audible alarm, press the Soft Touch Mute Alarm key (C) briefly once. This will
silence the alarm for 24 hours, the Display (B) will now flash showing the fault code and
indicating that the alarm has been muted. Should another fault occur while the alarm is
muted, a new alarm will sound. If the faults are not rectified, the alarm will sound again at the
expiration of 24 hours as a reminder that the plant is not operating correctly. The visual
alarms cannot be turned off until all faults are rectified.
Taylex ABS Home Owners Manual
©Copyright June 2017