Troubleshooting: Door
No product is being dispensed.
Cause: Low on mix. The MIX OUT light
is on.
Remedy: Add mix to the mix hopper.
Return to AUTO mode.
Cause: The power switch is in the OFF
position.
Remedy: Place the power switch in the
ON position and select AUTO.
Cause: Beater motor is out on reset,
BEATER OVERLOAD message
displayed.
Remedy: Turn the machine off. Press
the reset button. Restart the machine in
AUTO.
Cause: Machine not in AUTO mode.
Remedy: Select AUTO and allow
machine to cycle off before drawing
product.
Cause: The feed tube is not properly
installed.
Remedy: Make sure the feed tube is
properly installed.
Cause: Freeze-up in mix inlet hole.
Remedy: Call an authorized service
technician.
Product is collecting on top of the
freezer door.
Cause: The top o-ring on draw valve is
improperly lubricated or worn.
Remedy: Lubricate properly or replace
the o-ring.
Excessive mix leakage from the bottom
of the door spout.
Cause: Bottom o-ring on draw valve is
improperly lubricated or worn.
Remedy: Lubricate properly or replace
the o-ring.