6-4
OPERATING PROCEDURES
Models 8752 and 8756 with Horizon® Pump
Operating Procedures
6
15. Lubricate the O-rings.
Figure 6-11
16. Lubricate the inside of the freezer door spout(s), top
and bottom, and insert the draw valve(s) from the
bottom until the slot in the draw valve(s) comes into
view.
Figure 6-12
17. Install the adjustable draw handle(s). Slide the
O-ring(s) into the groove(s) on the pivot pin(s) and
lubricate.
Figure 6-13
18. Slide the fork of the draw handle(s) in the slot of the
draw valve(s). Secure with pivot pin.
Note: Model 8756 has three draw handles and two
pivot pins. Slide the fork of the draw handle in the slot
of the draw valve, starting from the right. Slide the
long pivot pin through the right and middle draw
handles. Secure the left draw handle with the short
pivot pin. The draw handles have a color identifier for
vanilla, twist, and chocolate. Be sure to install the
appropriate handle in the correct position.
Figure 6-14
Note: These machines feature adjustable draw
handles to provide the best portion control, giving a
better consistency quality to your product and
controlling costs. The draw handles can be adjusted
for different flow rates. See "Adjustable Draw Handle"
on page 5-3 for more information on adjusting these
handles.
19. Snap the design cap over the bottom of each door
spout.
Figure 6-15