OPERATING PROCEDURES
6-5
Models 8752 and 8756 with Horizon® Pump
Operating Procedures
6
20. Install the rear drip pan. Slide the rear drip pan into
the hole in the side panel.
Figure 6-16
21. Install the front drip tray and the splash shield
beneath the door spout(s).
Figure 6-17
Horizon
®
Pump Assembly
The purpose of the Horizon
®
pump is to meter a specific
amount of air and mix, and transfer this combination to
the freezing cylinder.
See Figure 4-5. for identification of parts during
assembly.
1. Inspect the rubber and plastic pump parts. These
parts must be in 100% good condition for the pump
and entire machine to operate properly. They cannot
properly serve their intended function if nicks, cuts, or
holes in the material are present.
Inspect the plastic pumps parts for cracks, wear, and
delamination of plastic.
Replace any defective parts immediately and discard
the old.
2. Lightly lubricate both sides of the pressure switch
diaphragm.
Note: Do not place the diaphragm in the pressure
switch cap.
Figure 6-18
3. Place the diaphragm on the front (face) of the
pressure switch housing and then screw the pressure
switch cap onto the pressure switch housing.
Figure 6-19
Note: The lubricant will act as an adhesive to place
the diaphragm on the end of the pressure switch
housing.
15037
Apply the appropriate
Taylor approved food safe lubricant.
Apply the appropriate
Taylor approved food safe lubricant.