OPERATING PROCEDURES
6-11
Models 8752 and 8756 with Horizon® Pump
Operating Procedures
6
4. Adjust the airflow to the desired setting. The flow rate
is factory set at 1.0 to 1.4 cfm.
Figure 6-43
5. Press the PUMP button to cancel operation.
6. Prime the machine according to the operating
instructions. Make sure the air has stopped flowing
from the prime plug hole before closing the prime
plug.
Priming
1. Prepare a sink with an approved 100 ppm sanitizing
solution (for example, 2 gal. [7.6 L] of Stera-Sheen
®
).
Note: Use warm water and follow the
manufacturer’s specifications.
2. Sanitize the mix tank, mix tank cover, mix probe, mix
storage cover, and funnel. Place the mix tank and
cover in the mix cabinet.
3. Insert the prongs of the mix probe inside the mix tank
and connect the mix probe in the socket receptacle.
Figure 6-44
4. Place the free end of the suction line down in the mix
tank.
Figure 6-45
5. Install the funnel. Fill the mix tank with fresh mix.
Note: Use only fresh mix when priming the freezer.
Figure 6-46
6. Remove the funnel and install the mix storage cover.
Close the mix cabinet door.
7. Place an empty pail beneath the door spout. Open
the draw valve and pull the prime plug up.
Figure 6-47
17043
15064
15181
15182
10778