OPERATING PROCEDURES
6-13
Models 8752 and 8756 with Horizon® Pump
Operating Procedures
6
Draining Product from the Freezing
Cylinder
1. Press the AUTO and MIX REF buttons to cancel
freezer operation.
2. Open the mix cabinet door and remove the mix
storage cover(s), mix tank cover(s), mix tank(s), and
mix probe(s). Empty the mix from the mix tank(s) into
a sanitized stainless steel rerun can.
3. Place the suction line in an empty pail in the mix
cabinet.
4. If local health codes permit the use of rerun, place a
sanitized, NSF-approved stainless-steel rerun
container beneath the door spout.
• Open the draw valve and press the WASH and
PUMP buttons.
• Drain all the mix from the freezing cylinder.
• When all the product stops flowing from the
door spout, close the draw valve and press the
WASH and PUMP buttons to stop operation.
• Place a sanitized lid on the rerun container and
place it in the walk-in cooler.
Note: If local health codes do not permit the use of
rerun, the product must be discarded. Follow the
instructions in the previous step, except drain the
product into a pail and properly discard the mix.
5. Repeat steps 3 and 4 for the other side of the freezer
on Model 8756.
Rinsing
1. Fill the empty pail in the mix cabinet with 2 gal. (7.6 L)
of cool, clean water. Place the free end of the suction
line in the pail of water.
2. Disconnect the pressure line from the check valve
and place it in the pail of water.
Figure 6-51
3. Press the PUMP button. This action causes the rinse
water to be pumped through the Horizon
®
pump and
out through the pressure line. After approximately
15 seconds, press the PUMP button to stop
operation.
4. Drain and connect the free end of the pressure line to
the check valve.
Figure 6-52
!
ALWAYS FOLLOW LOCAL HEALTH CODES.