ELECTRICAL CONNECTION
The electrical connection must be carried out in
accordance with the current standards and laws
in force and by an authorised electrician.
Warning this appliance must be earthed.
Connection to the electricity supply must be made
by an authorised electrician to a suitable isolating
switch in accordance with the requirements of SAA
Wiring Rules, AS/NZS 3000.
A cable of the correct rating must be used (see
Electrical components).
Means of disconnection shall be provided in the
xed wiring in accordance with the Australian wiring
rules.
Remember that the earth wire must be longer
than the phase wires.
Note: The power supply cable must be positioned
so that no part of cable can come into contact with
any surface which could reach temperatures in
excess of 75 K.
ADJUSTMENTS
Always disconnect the appliance from
the electricity supply before making any
adjustment.
All seals must be replaced by the technician
following any adjustment or regulation.
The adjustment of the reduce rate (simmer)
must be undertaken only with burners
functioning on natural gas while in the case of
burners functioning on L.P.G., the screw must
be locked down fully (in clockwise direction).
“Primary air adjustment” on hob gas burners
is unnecessary.
If the appliance cannot be adjusted to perform
correctly refer to the authorised service
provider in your area.
INSTRUCTIONS FOR THE INSTALLER
21
TAPS (g. 21)
All gas taps are male cone type with only one way of
passage. Adjustment of the «Reduced rate» position
as follows:
Turn the burner on and place the knob on the
«Reduced rate» position (small ame).
Remove the knob (A) of the tap which is attached by
simply applying pressure to the rod.
In the case of taps with ame failure device, the
adjustment screw (V) is on the side of the stem
(g. 21).(use a small screwdriver C)
Check that the ame does not go out when the knob
is sharply switched from the «Full on» to «Reduced
rate» positions.
NOTE:
Hot Plate Ignition Failure
Check alignment of burner holes to electrode.
Check aeration sleeve for adjustment for gas type,
location and ambient conditions.
No spark, check ignition box failure or power supply.
Before Leaving
Check all connections for gas leaks with soap and water.
DO NOT use a naked ame for detecting leaks. Ignite
all burners to ensure correct operation of gas valves,
burners and ignition.
Turn gas taps to low ame position and observe stability
of the ame. When satised with the cooker, please
instruct the user on the correct method of operation.
In case the appliance fails to operate correctly after all
checks have been carried out, refer to the authorised
service provider in your area.