EN4
601 1000 ppm eq
400 600 ppm eq
Your CO2 monitor measures and displays the CO2 in PPM with color
ventilation recommendations:
The icons flash when the current CO2 exceeds 2000 ppm.
To set high alert and low alert of CO2 and humidity
1) Press and hold the CO2/RH% / SETbutton (C4), the CO2 digits400
(default) flash and the icon (A1) appears. Press the +“ or the “-“ button
to adjust the low alert level of CO2 in steps of +/- 10 PPM. Lowest alert level
is 400 PPM.
2) Press the CO2/RH% / SETbutton (C4) again, the CO2 digits “2000
(default) flash and the icon (A2) appears. Press the “+“ or the “- button
to adjust the high alert level of CO2 in steps of +/- 10 PPM. The highest
CO2 alert level is 5000 PPM.
3) Press the CO2/RH% / SETbutton (C4) again, the humidity digits “35%”
(default) flash and the icon (A1) appears. Press the “+“ or the “-“ button
to adjust the low alert level of RH% in steps of +/-1%. Lowest alert level is
20%.
4) Press the CO2/RH% / SETbutton (C4) again, the humidity digits “70%”
(default) flash and the icon (A2) appears. Press the “+“ or the “-“ button
to adjust the high alert level of RH% in steps of +/-1%. Highest alert level is
95%.
5) Press CO2/RH% / SETbutton (C4) again to confirm and end setting.
The WL 1030 returns to normal display mode.