4-84
perform UP or DOWN.
. Output frequency will be UP or DOWN following the acceleration and deceleration
time.
When the following situations occur, it will display an error message of "SE02 DI terminal
Error" (SE02):
(1). Only set a single UP or Down command.
(2). Start UP / Down command and the acceleration / deceleration prohibition
command simultaneously.
.For the examples of UP/DOWN wiring and time, please refer to figure 4.3.19 and
figure 4.3.20.
Figure 4.3.19 UP/DOWN wiring example
Figure 4.3.20 Up / Down command time diagram
. When using the UP / Down command, if the operation command is input, the
output frequency will accelerate to the lower limit of frequency reference (00-13).
. When using the UP / Down command, the output frequency is limited by the upper