4-112
(11) Added to AI1 ( Setting = 10)
. When 04-05 (AI2 function selection) is set to 10 (and add to AI1), then the frequency
reference value equaling to the AI2 analog input signal will be added to AI1 as a bias.
Refer to the following figure 4.3.49.
10V
(20mA)
0V
(4mA)
100%
-
100%
-10V
Frequency
Reference
Bias
Terminal AI2
analog input
Figure Operation of being added to Al1 as bias
. Example:
. When 04-02 (AI1 gain value) = 100%, 04-03 (AI2 gain value) = 0%, and terminal AI2
is set to 2V, if the input terminal AI1 is 0V,the reference frequency of terminal AI1 will
be 20 %.
(12) Positive torque limit ( Setting = 11)
(13) Negative torque limit ( Setting = 12)
(14) Regenerative torque limit ( Setting = 13)
(15) Positive / negative torque limits ( Setting = 14)
. For more details on torque limits, please refer to Parameter 21 - torque function
group.
(16) Torque reference / torque limit of speed control ( Setting = 15)
(17) Torque compensation ( Setting =16)
. For more details about torque control functions, please refer to Parameter 21 -
torque function group.