4-106
Figure 4.3.16 Multi-function digital input and related parameters
Table 4.3.27 Multi-function digital input setting ( 03-00 to 03-05 ) (“O”:Enable, “X”:Disable)
Value
Function
Description
Control Mode
Name LCD Display V/F SLV
SLV
0
Forward/Stop
command
2-Wire (FWD-RUN)
2- wire Forward/Stop command
(ON:Forward operation command).
O O O
1 Reverse/Stop command 2-Wire (REV-RUN)
2- wire Reverse/Stop command
(ON:Reverse operation command).
O O O
2
Multi-speed/position
setting command 0
Muti-Spd/Pos Ref 0
Multi-Speed Reference / Position
Reference 0
O O O
3
Multi-speed/position
setting command 1
Muti-Spd/Pos Ref 1
Multi-Speed Reference /Position
Reference 1
O O O
4
Multi-speed/position
setting command 2
Muti-Spd/Pos Ref 2
Multi-Speed Reference /Position
Reference 2
O O O
5
Multi-speed/position
setting command 3
Muti-Spd/Pos Ref 3
Multi-Speed Reference /Position
Reference 3
O O O
6
Forward jog run
command
FJOG
ON:Forward operation in jog mode
(00-18).
O O O
7
Reverse jog run
command
RJOG
ON:Reverse operation in jog mode
(00-18).
O O O
8
UP frequency
increasing command
UP command
ON:Command of output frequency
increasing (only used by support of
DOWN command).
O O O
9
DOWN frequency
decreasing command
DOWN command
ON:Command of output frequency
decreasing (only used by support of
UP command).
O O O
10
Acceleration/decelerati
on time selection 2
Acc/Decel Time
Selection 1
Acceleration/deceleration time selection
command 1
O O O
11
Inhibit Acceleration
/deceleration command
ACC/DEC Inhibit
ON:Acceleration/ deceleration
prohibition
O O O
12
Main/ Alternative Run
Switch Function
Run Change Sel
Run Command Source is set in parameter
of alternative frequency command
(00-03)
O O O
13
Main/ Alternative
Frequency Switch
Function
Freq Change Sel
Frequency Command Source is set in
parameter of alternative frequency
command (00-06)
O O O
14
Emergency Stop
(decelerate to zero and
stop)
E-Stop ON:Emergency stop input O O O