4-122
Function Detection operation of frequency confirmation Description
Output
frequency
detection 1
Output frequency detection 1
signal is ON in acceleration when
the output frequency rises above
the frequency detection level
(03-13) + frequency detection
width (03-14).
Output frequency detection 1
signal is OFF in deceleration
when the output frequency
declines to the frequency
detection level 4 (03-50).
Any of the digital outputs function
(03-11, 03-12 or 03-39) can be
set to 4 (Output frequency
detection 1).
Output
frequency
detection 2
Output frequency detection 2
signal is OFF in acceleration
when the output frequency rises
above the frequency detection
level (03-13) + frequency
detection width (03-14).
Output frequency detection 2
signal is ON in deceleration when
the output frequency declines to
the frequency detection level 4
(03-50).
Any of the digital outputs function
(03-11, 03-12 or 03-39) can be
set to 5 (Output frequency
detection 2).
Output
frequency
detection 3
Output frequency detection 3
signal is ON in acceleration when
the output frequency rises above
the frequency detection level 2
(03-44) + frequency detection
width 2 (03-45).
Output frequency detection 3
signal is OFF in deceleration
when the output frequency
declines to the frequency
detection level 5 (03-51).
Any of the digital outputs function
(03-11, 03-12 or 03-39) can be
set to 50 (Output frequency
detection 3).
Output
frequency
detection 4
Output frequency detection 4
signal is OFF in acceleration
when the output frequency rises
above the frequency detection
level 2 (03-44) + frequency
detection width 2 (03-45).
Output frequency detection 4
signal is ON in deceleration when
the output frequency declines to
the frequency detection level 5
(03-51).
Any of the digital outputs function
(03-11, 03-12 or 03-39) can be
set to 51 (Output frequency
detection 4).