Chapter 3 Environment description and installation
3-16
Over load protection Inverter rated current 150%/1min
International
conformity
UL/CE
Over voltage 230V Class: DC voltage >400V 460V Class: DC voltage >800V
Under voltage 230V Class: DC voltage <190V 460V Class: DC voltage <380V
Instantaneous power
loss restart
Set to enable or disable
Stall prevention ACC/DEC/ Operation stall prevention and stall prevention level.
Output terminal
short circuit
Electronic circuit protection
Other faults Electronic circuit protection
Protective Functions
Other functions
Over current, over voltage, under voltage, over load, instantaneous power loss
restart, ACC/DEC/ Operation stall prevention, output terminal sort circuit,
grounding error, reverse limit, directly start as power on and fault reset limit.
Note1: The setting resolution of above 100 Hz is 1Hz when controlled by keypad, and 0.01
Hz when controlled using computer(PC) or programmable controller(PLC).
Note2: EV-1P2~101-H12P2~201-H1/H3401~403-H3 type (Fc=10KHz) with option filter
complies with EN61800-3 first environment restricted distribution.
EV-202~203-H1/H3 type (Fc=10KHz) with option filter complies with EN61800-3 first
environment unrestricted distribution.
EV-2P2~201-H1F type (Fc=10KHz) & EV-202~203-H1F type (Fc=6KHz) with Build in
filter complies with EN61800-3 first environment unrestricted distribution.
(IP65) EV-2P2~403-H1(3)FN4(S) series & EV-401~403-H3F type (Fc=10KHz) with
Build in filter complies with EN61800-3 first environment restricted distribution.