VERTICAL AMPLIFIER
QUIESCENT VOLTAGE READINGS were obtained under the following
conditions:
Oscilloscope:
POWER.................................................... ON
Type TU-7:
INPUT SIG NAL...................................... None
VERTICAL POSITION
..........................
Centered*
TEST FUNCTION
....................................
COMMON MODE
*lf a letter-series or ‘1'-series plug-in unit is used, adjust the plug-in
unit Vertical Position control to obtain zero volts reading between pins
1 and 3 of the interconnecting plug.
Also see IMPORTANT note on Block Diagram.