Loading...
DPO7104C
Scale 10% - 90%
1 mV/div - 1.99 mV/div 1.2 ns
2 mV/div - 4.99 mV/div 580 ps
5 mV/div - 9.9 mV/div 300 ps
10 mV/div - 1 V/div 300 ps
DPO7054C
Scale 10% - 90%
1 mV/div - 1.99 mV/div 1.2 ns
2 mV/div - 4.99 mV/div 680 ps
5 mV/div - 9.9 mV/div 460 ps
10 mV/div - 1 V/div 460 ps
Step response settling time,
typical, >20 GHz models
The time by which the step response enters and stays below the indicated % error. Step transition
occurs at the 50% amplitude point of the step leading edge.
DSP off
Instrument Gain setting (FS) Settling Error Time
MSO/
DPO73304DX,
62.5 mV, 100 mV, 200 mV, <6% 150 ps – 400 ps
MSO/
DPO72504DX,
500 mV, 1 V, 1.2 V, 1.4 V, <5% (<5.5% 400 ps – 3 ns
MSO/
DPO72304DX
2 V, 4 V MSO/
DPO73304DX)
<3%
3 ns – 1 ms
DSP on (fastest BWE setting) DSP on (fastest BWE setting) Instrument Gain setting (FS) Settling
Instrument Gain setting (FS) Settling Error Time
MSO/
DPO73304DX
62.5 mV, 100 mV, 200 mV, <3.5% 150 ps – 400 ps
MSO/
DPO72504DX,
500 mV, 1 V, 1.2 V, 1.4 V, <2.5% 400 ps – 3 ns
MSO/
DPO72304DX
2 V, 4 V <1.5% 3 ns – 1 ms
Specifications (MSO70000C/DX, DPO70000C/DX, and DPO7000C series) Vertical system analog channels