13
•
•
•
•
3.6 Changing gas
Warning : The following procedures must be undertaken by authorized service personnel.
Your cooker has been designed to use either liquefied petroleum gas (propane or butane), or
natural gas. The gas burners can be adapted to these different types of gas, by replacing the
corresponding injectors and adjusting the minimum flame length of each burner. The steps
below must be strictly carried out:
Changing Injectors:
Cooktop burners:
Shut off main gas and disconnect the electrical outlet.
Remove the burner cap and the upper burner (Figure 9).
Unscrew the injectors. For this, use a 7mm spanner (Figure 10).
Install the new injectors in accordance with the type of gas used, as shown on the technical data
table. Be careful to tighten straight the new injectors, because if you mount them sideways, you will
damage the thread of the rack and the rack will need to be changed (and it will not be in guarantee
extent).
3. INSTALLATION
!
Figure 10
Injector
Spanner
Figure 9