DIP Switch Table
DIP switch
settings
Ports powered
at startup
Startup delay
of first port(s)
Port interval(s) Remark
1 1 1 1 All ports 0 0 Standard settings
0 0 0 0 None NA NA
No power, only data.
Switches activated after startup,
will power corresponding ports
1 0 0 0 Port 1 0 NA 1 port powered
0 1 0 0 Port 1 + 2 0 0.5 2 ports powered
1 1 0 0 Port 1 + 2 + 3 0 0.5 3 ports powered
0 0 1 0 All ports 0 0.5 delay 0 to 1.5
1 0 1 1 All ports 2 0.5 delay 2 to 3.5
0 1 1 0 All ports 4 0.5 delay 4 to 5.5
1 1 1 0 All ports 6 0.5 delay 6 to 7.5
0 0 0 1 All ports 8 0.5 delay 8 to 9.5
1 0 0 1 All ports 10 0.5 delay 10 to 11.5
0 1 0 1 All ports 12 0.5 delay 12 to 13.5
1 1 0 1 All ports 14 0.5 delay 14 to 15.5
0 0 1 1 All ports 16 0.5 delay 16 to 17.5
1 0 1 1 All ports 18 0.5 delay 18 to 19.5
0 1 1 1 None NA 0 Remote control*
*planned for future releases
General Network Extender Guidelines
The maximum distance between the central unit and the first Plixus network extender or
delegate unit in the branch is 100 m.
The maximum distance between two Plixus network extenders is 100m.
PLIX US NEX T 34