3G Tracking Device Installation Manual
1
2
3
4
5
6
Color
Red
Yellow
Yellow
Black
Purple
Purple
Pin
1
2
3
4
6
5
Pin Name
10-30V DC (+)
Ignition
1-Wire Data
Ground (-)
1-Wire Power
Digital Output 1
Description
Power supply for module.
Digital input 1
Data channel for Dallas devices
Ground pin
+ 3,8 V output for 1-Wire®
Digital output. Open collector
output. Max. 150mA.
Most installations require only the first 3 wires. Red, Black and Yellow
(Power, Ground and ignition). Other wires are typically used for additional
monitoring
requirements, such as temperature monitoring or Driver ID.
Any un-used wires should ideally be coiled up and kept for potential future
use, but can be cut if necessary (if cutting, it is our recommendation that at
least a 3 – 6cm lead be left so as to supply a fly lead for future connection
of additional monitoring devices).