8. Empty and rinse out the debris trough (Figure 63).
FIG. 63
9. Inspect the cylindrical brushes for wear. Rotate
brushes from front--to--rear every 50 hours (Figure
64). Replace when worn to a length of 15mm
(5/8”).
FIG. 66
12. Check the condition of the squeegee blade wiping
edge (Figure 67). Rotate blade if worn (See
SQUEEGEE BLADES).
FIG. 67
13. Clean the machine with an all purpose cleaner and
damp cloth (Figure 68).
FOR SAFETY: When cleaning machine, do not
power spray or hose off machine. Electrical
malfunction may occur.
FIG. 68
T5 –Maintenance
(Page 7 of 15)
T5 9002333 REV.02 (07-06) 13
Cylindrical Brush Model
15mm
(5/8”)
Cylindrical
Brush Model
FIG. 64
10. Remove debris buildup from the underside of the
cylindrical brush scrub head, including the idler
plates and drive hubs (Figure 65).
Cylindrical Brush Model
FIG. 65
11. Wipe the squeegee blades clean (Figure 66). Store
the squeegee assembly in the raised position to
prevent blade damage.
M