D2
1 RED
13 BLK
14
13 BLK
2
POS
RIBBON CABLE CONNECTOR P6
T5 - Key ON Power Distribution
STANDOFF 2
CR1
NEG
KEY
SWITCH
2
3
26
34
4
PIN J6-24
PIN J6-18
1 RED
1 RED
13 BLK
POST J11 POST J7
TOUCH
PANEL
F1
100A
+
1 RED 1 RED
1 RED
SW3
SW1
CHARGER
INTERLOCK
-
CONDITIONS: Key ON, all machine functions OFF
i
If Charger Plug is connected to battery charger, ALL machine
functions will be disabled when Key Switch is turned ON
!
Be cautious when working near Control Board -
Battery voltage is always present, even with Key OFF
i
If machine is not equipped with optional Emergency
Stop Switch, jumper wire 17/Purple will replace SW2
CB2
10A
PIN J6-13
TO CB2 PROTECTED
COMPONENTS
14
14
14
FLYBACK PATH
i
The Flyback Path prevents high voltage
spikes when a component is turned OFF
Wiring Color Codes
(Unless otherwise marked)
0
1
2
3
4
5
6
7
8
9
Tan
Pink
Brown
Orange
Yellow
Green
Blue
Purple
Gray
White
Right Most Digit
of Wire Number
Color of Wire
= Battery Negative
or Logic Ground
= Battery Positive
or Logic High
i
The troubleshooting information from this page forward applies to machines
with On-Board or Off-Board Chargers unless otherwise noted
+
-
6 VDC
+
-
6 VDC
+
-
6 VDC
+
-
6 VDC
D1
EMERGENCY STOP
SWITCH (OPTION)
MAIN
CONTACTOR
CR1
15
5
5
5
56
17
SW2
5
4
BRAKE RELAY
CR2
JUMPER
(STANDARD)
66
6
5
CONTROL BOARD
v
1 RED
CB1
5A
4
PIN J6-17
PIN J6-5
38 T5 9002333 REV.02 (11-07)