MAINTENANCE
Tennant T5 (06- 15)
39
TROUBLESHOOTING - Continued
PROBLEM CAUSE SOLUTION
FaST Model: FaST System does
not operate or operate correctly
FaST system switch is not turned on Turn on FaST system switch
FaST- PAK supply hose not connected Connect supply hose
Clogged FaST- PAK supply hose or
connectors
Soak in warm water to unclog
Empty FaST- PAK carton Replace FaST- PAK carton
Kink in FaST- PAK supply hose Undo hose kink
Clogged FaST solution system Contact Service Center
Faulty FaST system on/off switch Contact Service Center
Faulty pump Contact Service Center
Clogged solution tank filter Drain solution tank. Remove solution
tank filter, clean and reinstall
Clogged detergent orifice/filter screen Replace orifice/filter screen
(See FaST SYSTEM
MAINTENANCE)
Clogged FaST solution inlet filter Contact Service Center
Faulty control board Contact Service Center
ec-H2O NanoClean Models (ec-H2O models labeled ec-H2O NanoClean)
PROBLEM
CAUSE SOLUTION
ec-H2O system indicator
light blinking green/red
W ater conditioning cartridge has expired Replace cartridge (See ec-H2O NanoClean
WATER CONDITIONING CARTRIDGE
REPLACEMENT)
ec-H2O system indicator
light is red or blinking* red
ec-H2O system fault has been detected Contact Service Center
*Verify if cleaning detergent was added to solution tank. If ec-H2O system was operated with cleaning detergent, drain solution
tank, add clear water and operate the ec -H2O system until the indicator light code clears.
ec-H2O Models (Manufactured before ec-H2O NanoClean models)
PROBLEM
CAUSE SOLUTION
ec- H2O system indicator light
blinks red and alarm sounds
Mineral deposit build- up in module Flush module (See ec- H2O MODULE
FLUSH PROCEDURE). If indicator
light starts flashing within 1- 10
seconds, repeat flush procedure. If in-
dicator light starts flashing after a
minute of scrubbing, the water may
have low conductivity.
Low water conductivity Add17mlofsalttoevery85Lof
water.
ec- H2O system indicator light
solid red
Defective module Contact Service Center
ec- H2O system indicator light
does not turn on
Defective light or module Contact Service Center
No water flow Clogged module Contact Service Center
Defective solution pump Replace solution pump

Table of Contents