Questions and Answers

  • A
    Anthony JosephAug 8, 2025
    Why does my Tennsmith LM1014 motor overheat?
    • R
      richard72Aug 8, 2025
      If the Tennsmith Industrial Equipment motor overheats, first check the connection diagram on the conduit box cover and correct the wiring to ensure it's connected for the proper supply voltage. Also, make sure the supply voltage is correct. Increase air flow by using a continuous running auxiliary fan and ensuring unobstructed air flow. Ensure cool air gets to the motor, using ducting if needed. If overloaded, select a larger unit. If single phasing occurs due to a break, loose connection, or blown fuse, repair supply lines and replace fuses.
  • R
    ramseysabrinaAug 12, 2025
    What to do if fuses blow or motor overcurrent protection trips immediately on my Tennsmith LM1014?
    • T
      Terry LynnAug 12, 2025
      If fuses blow or the motor overcurrent protection trips immediately on your Tennsmith Industrial Equipment, the cause may be a short circuit in power supply conductors or in the motor, a ground fault or winding to winding short circuit in the motor, or the motor being improperly connected. Correct any fault conditions, have the motor repaired by a qualified service shop if there's a ground fault or short circuit, and check the connection diagram in the conduit box cover to correct the wiring.
  • T
    timothysmithAug 16, 2025
    What to do if my Tennsmith LM1014 motor does not run?
    • K
      kestradaAug 16, 2025
      If the Tennsmith Industrial Equipment motor does not run, the cause may be a blown fuse, activation of the motor protection device, or a faulty motor protection device. Determine and correct the cause of failure and replace the fuse. Reset the protective device and identify/correct the cause for its activation. Check the protection device for faults.
  • B
    beasleykimberlyAug 20, 2025
    Why will my Tennsmith LM1014 motor not start or starts sluggishly?
    • P
      Paul ChandlerAug 20, 2025
      If your Tennsmith Industrial Equipment motor will not start or starts sluggishly, check the connection diagram in the conduit box cover and correct the wiring to ensure it's connected for the proper voltage. Also, ensure a stable power supply to prevent large voltage or frequency fluctuations at starting.
  • M
    Makayla LongAug 26, 2025
    What to do if Tennsmith Industrial Equipment motor will not start in Star Connection but will start in Delta connection?
    • L
      Leslie MoralesAug 26, 2025
      To resolve this issue with your Tennsmith Industrial Equipment, start the motor directly in Delta Connection if possible. Otherwise, consider using a larger motor. If the issue is a faulty contact in the Star/Delta starter, correct the fault condition.
  • W
    William RobinsonAug 29, 2025
    What to do if my Tennsmith LM1014 Industrial Equipment motor hums and draws high current?
    • K
      Katherine RamirezAug 29, 2025
      If the Tennsmith Industrial Equipment motor hums and draws high current, have the motor repaired by a qualified service shop because the winding may be faulty or defective.
  • C
    curtisrangelSep 2, 2025
    How to correct the direction of my Tennsmith LM1014 motor?
    • Q
      qvazquezSep 3, 2025
      If the Tennsmith Industrial Equipment motor runs in the wrong direction, switch two supply leads.