Lists the essential features and capabilities of the RGT-MT device.
Details important safety precautions and usage guidelines for the device.
Discusses crucial points for effective compensation setup and configuration.
Guidance on selecting and connecting current transformers for the device.
Explains NTC sensor connection and device cleaning procedures.
Explains various status indicators on the device screen.
Describes the touch-screen area for viewing measurements and changing settings.
Displays phase-neutral and phase-to-phase voltage values.
Shows phase-neutral voltage and current values.
Displays voltage, frequency, active, and reactive power.
Shows power factor, ratios, and total energy consumption.
Displays THD-V and THD-I values for each phase.
Shows reactive system records and capacitor/reactor step values.
Displays cosine values and harmonic voltage up to the 61st harmonic.
Displays harmonic current values up to the 61st harmonic.
Shows demand values and min/max/average current and voltage.
Allows starting the current transformer test and changing the CT ratio.
Configures voltage harmonic control mode, set values, and delay.
Configures harmonic and voltage protection modes and limits.
Sets generator compensation mode and inductive set value.
Sets inductive/capacitive alarm modes and ratio thresholds.
Configures temperature control mode and limits.
Configures remote communication settings via Modbus.
Sets drive, discharge, and settling times for capacitor steps.
Allows manual entry of capacitor or shunt reactor step values.
Performs automatic measurement of selected capacitor/reactor steps.
Configures PFC (compensation) and TCR (SVC) modes and step counter.
Manually tests the output and connection of capacitor/reactor steps.
Accesses settings for device configuration like language and factory defaults.
Performs initial device setup and changes the device language.
Sets up password protection for the device.
Deletes specific data records like energy values or power analysis samples.
Restores the device to its original factory default settings.
Explains the process of restoring the device to factory default settings.
Describes how to return to the general menu settings.
Details remote communication setup using RS485 with a GSM modem.
Explains remote communication setup using RS485 with an Ethernet modem.