Programming Worksheets & Defaults Premier 412/816/832 Installation Manual
92 INS159-13
Global Programming
[ ]
0
0: Not Used; 1: Auxiliary Tamper; 2: Remote Reset; 3: Line Fault; 4: Panic Alarm; 5: Silent PA; 6: Latched Key
Switch; 7: Momentary Key Switch
Menu: 
Miscellaneous Options 1
Page 38
Enable Bell
Squawk on
AWAY
Arm/Disarm
Enable Bell
Squawk on
STAY
Arm/Disarm
Disable AC Fail
Ack.
Disable
Open/Close
Reporting on
STAY Arm
Cross/Double
Knock Timer is
in Minutes
Disable Zone
Bypass when
Armed
Activated
Zones Cause
Alarm during
Exit
Control Timer 4
Performs Battery
Test
1
2
3
4
5
6
7
8
[ ] 
[ ]
[ ] 
[ ]
[ ] 
[ ]
[ ] 
[ ]
Menu: 
Miscellaneous Options 2
Page 39
Disable
Service Fault
Ack.
Enable User
Reset for
Alarms
Disable On-line
Printing
Enable UK Bell
Module
Enable DD243:
2002 Options
Enable
Confirmation
after Entry
Time-Out
Invert Auxiliary
Input Operation
Auto BST/GMT
Time Change
1
2
3
4
5
6
7
8
[ ] 
[ ]
[ ] 
[ ]
[ ] 
[ ]
[ ] 
[ ]
Menu: 
Miscellaneous Options 3
Page 39
Allow User
Tamper
Reset
Allow Engineer
Access when
Armed
1
2
[ ] 
[ ]
Menu: 
EN50131
Page 39
Confirm Low
fob Battery
on Arm
Soak Test
Active
Indication
Soak Test
Acknowledge
Required
Entry Stray
Notification
Delay
Entry Timeout
Notify Delay
Cable Cut
Expander
Tamper
User Code
Entry Timed
Power Failure
Latch
1
2
3
4
5
6
7
8
[ ] 
[ ]
[ ] 
[ ]
[ ] 
[ ]
[ ] 
[ ]
Remote Keypad Programming
Menu: 
Remote Keypad Options 1
Page 42
Keypa
d
Partition 1
Operation
Partition 2
Operation
Partition 3
Operation
Partition 4
Operation
Permanent
Keypad
Status
Display
Press any Key
for Display
Display Zones
vs. Partitions
Wrong Code
Attempts =
Code Tamper
1
2
3
4
5
6
7
8
1
[ ]
[ ]
[ ]
[ ]
[ ] 
[ ]
[ ] 
[ ]
2
[ ]
[ ]
[ ]
[ ]
[ ] 
[ ]
[ ] 
[ ]
3
[ ]
[ ]
[ ]
[ ]
[ ] 
[ ]
[ ] 
[ ]
4
[ ]
[ ]
[ ]
[ ]
[ ] 
[ ]
[ ] 
[ ]
5
[ ]
[ ]
[ ]
[ ]
[ ] 
[ ]
[ ] 
[ ]
6
[ ]
[ ]
[ ]
[ ]
[ ] 
[ ]
[ ] 
[ ]
Menu: 
Remote Keypad Options 2
Page 39
Keypa
d
Code Tamper
Causes a
Tamper Alarm
Keypad
Activation of
Fire Alarm
Keypad
Activation of
Medical Alarm
Keypad
Activation of
PA Alarm
Keypad PA
Alarm is Silent
Quick Arm
with Keypad
ARM Key
Quick Disarm
with Keypad
DISARM Key
Quick Bypass
with Keypad
BYPASS Key
1
2
3
4
5
6
7
8
1
[ ]
[ ]
[ ]
[ ]
[ ] 
[ ]
[ ] 
[ ]
2
[ ]
[ ]
[ ]
[ ]
[ ] 
[ ]
[ ] 
[ ]
3
[ ]
[ ]
[ ]
[ ]
[ ] 
[ ]
[ ] 
[ ]
4
[ ]
[ ]
[ ]
[ ]
[ ] 
[ ]
[ ] 
[ ]
5
[ ]
[ ]
[ ]
[ ]
[ ] 
[ ]
[ ] 
[ ]
6
[ ]
[ ]
[ ]
[ ]
[ ] 
[ ]
[ ] 
[ ]
Menu: 
Remote Keypad Options 3
Page 42
Keypa
d
Fire Alarm
Tones from
Keypad
Burglary
Alarm Tones
from Keypad
Trouble
Tones from
Keypad
Acceptance
Tones from
Keypad
Error Tones
from Keypad
Chime Tones
from Keypad
Entry Tones
from Keypad
Exit Tones
from Keypad
1
2
3
4
5
6
7
8
1
[ ]
[ ]
[ ]
[ ]
[ ] 
[ ]
[ ] 
[ ]
2
[ ]
[ ]
[ ]
[ ]
[ ] 
[ ]
[ ] 
[ ]
3
[ ]
[ ]
[ ]
[ ]
[ ] 
[ ]
[ ] 
[ ]
4
[ ]
[ ]
[ ]
[ ]
[ ] 
[ ]
[ ] 
[ ]
5
[ ]
[ ]
[ ]
[ ]
[ ] 
[ ]
[ ] 
[ ]
6
[ ]
[ ]
[ ]
[ ]
[ ] 
[ ]
[ ] 
[ ]

Table of Contents