Quick Reference Guide Premier 412/816/832 Installation Manual
82 INS159-13
Use Delay Timer to Defer Non-Zone Restorals
Inhibit Keyswitch Operation Upon EOL Tamper
Away Arm Overrides Alarm Transmission Delay
Defer Reporting of Zone Restorals
Use Delay Timer to Defer Zone Restorals
Away Arm Exit Error Doesn’t Sound Bell
Zone Test - Silence on No Violation
Alarm Status Light Indicates Fire
Enable Entry/Exit Tones for Panel Speaker
Enable Cross Partitioning
Enable EN 50131-1 Requirements
Reinstate Bypassed Zones on Disarm
Invert Panel Bell/Siren Output
Panel Output 1 Supervised for Faults
Panel Output 2 Supervised for Faults
Siren/Bell Output Supervised for Faults
Panel Box Tamper Switch Monitored
Auxiliary Fuse Supervised for Faults
Battery Supervised for Faults
AC Mains Supply is Monitored
Telephone Line Is Monitored
Not Used
Auxiliary Tamper
Remote Reset
Telephone Line Monitor
Panic Alarm
Silent PA
Latched Key switch
Momentary Key switch
Enable Bell Squawk on AWAY Arm/Disarm
Enable Bell Squawk on STAY Arm/Disarm
Disable AC Fail Acknowledgement
Disable Open/Close Reporting on STAY Arm
Cross/Double Knock Timer is in Minutes
Disable Zone Bypass when Armed
Activated Zones Cause Alarm during Exit
Control Timer 4 Performs Battery Test
Disable Service Fault Acknowledgement
Enable User Reset for Alarms
Disable Online Printing
Enable Bell Module and UK Options
Enable DD 243:2002 Options
Enable Confirmation after Entry Time-Out
Invert Auxiliary Input Operation
Auto BST/GMT Time Change
Enable User Tamper Reset
Allow Engineer Access when Armed
Fob Low Battery Arming
Indicate Zone Soak Test
Soak Test Acknowledgement
Entry Stray Notification
Entry Timeout Notification
Expander Lost
User Code Entry
AC & Battery Fail Latch
Programming Remote Keypads
Partition 1 Operation
Partition 2 Operation
Partition 3 Operation
Partition 4 Operation
Permanent Keypad Status Display
Press Any Key for Display
Display Zones vs. Partitions
Wrong Code Attempts = Code Tamper
Code Tamper Causes a Tamper Alarm
Keypad Activation of Fire Alarm
Keypad Activation of Medical Alarm
Keypad Activation of PA Alarm
Keypad PA Alarm is Silent
Quick Arm with Keypad ARM Key
Quick Disarm with Keypad DISARM Key
Quick Bypass with Keypad BYPASS Key
Fire Alarm Tones from Keypad
Burglary Alarm Tones from Keypad
Trouble Tones from Keypad
Acceptance Tones from Keypad
Error Tones from Keypad
Chime Tones from Keypad
Entry Tones from Keypad
Exit Tones from Keypad
Enable Keypad Zones (RKP8/16 Plus & Premier LCD/LCD-P/LCDL/LCDL-P)
Disable Keypad Lid Tamper
Zone Shift by 4
Zone Shift by 8
Zone Shift by 16
Programming Remote Expanders
Partition 1 Operation
Partition 2 Operation
Partition 3 Operation
Partition 4 Operation
Fire Alarm Tones from Expander
Burglary Alarm Tones from Expander
Trouble Tones from Expander
Acceptance Tones from Expander
Error Tones from Expander
Chime Tones from Expander
Entry Tones from Expander
Exit Tones from Expander