Premier 48, 88, 168 & 640 Installation Manual Programming the Control Panel
INS176 81
No Type Event Reporting Group Contact ID SIA ID
57 Installer Programming End Alarm Maintenance 628 LS User No
Restore Not Reported - - -
58 Panel Box Tamper Alarm Tamper 145 TA 00
Restore Restore 145 TR 00
59 Bell Tamper Alarm Tamper 145 TA Device ID **
Restore Restore 145 TR Device ID **
60 Auxiliary Tamper Alarm Tamper 145 TA Device ID **
Restore Restore 145 TR Device ID **
61 Expander Tamper Alarm Tamper 145 TA Device ID **
Restore Restore 145 TR Device ID **
62 Keypad Tamper Alarm Tamper 145 TA Keypad No *
Restore Restore 145 TR Keypad No *
63 Expander Trouble (Network Error) Alarm Tamper 333 ET Device ID **
Restore Restore 333 ER Device ID **
64 Keypad Trouble (Network Error) Alarm Tamper 333 ET Keypad No *
Restore Restore 333 ER Keypad No *
65 Fire Zone Tamper Alarm Tamper 373 FT Zone No
Restore Restore 373 FJ Zone No
66 Zone Tamper Alarm Tamper 383 TA Zone No
Restore Restore 383 TR Zone No
67 Keypad Lockout Alarm Tamper 421 JA Keypad No *
Restore Not Reported - - -
68 Code Tamper Alarm Alarm Tamper 421 JA Keypad No *
Restore Not Reported - - -
69 Soak Test Alarm Alarm Test - - Zone No
Restore Restore - - Zone No
70 Manual Test Call Alarm Test 601 RX 00
Restore Not Reported - - -
71 Automatic Test Call Alarm Test 602 RP 00
Restore Not Reported - - -
72 User Walk Test Start/End Alarm Test 607 TS User No
Restore Restore 607 TE User No
73 NVM Defaults Loaded Alarm Not Reported - - Zone No
Restore Not Reported - - Zone No
74 First Knock Alarm Not Reported - - -
Restore Not Reported - - -
75 Door Access Alarm Not Reported - - -
Restore Not Reported - - -
76 Part Arm 1 Alarm Not Reported - - -
Restore Close 401 CL User No
77 Part Arm 2 Alarm Not Reported - - -
Restore Close 401 CL User No
78 Part Arm 3 Alarm Not Reported - - -
Restore Close 401 CL User No
79 Auto Arming Start Alarm Not Reported - - -
Restore Close 401 CL 000
80 Confirmed Alarm Alarm Alarm 139 BV Zone No
Restore Not Reported - - -
81 Prox TAG Alarm Not Reported - - -
Restore Not Reported - - -
82 Access Code Changed/Deleted Alarm Not Reported - - -
Restore Not Reported - - -
83 Arm Failed Alarm Not Reported - - -
Restore Not Reported - - -