EasyManua.ls Logo

Textron Cessna 208B - Transponder Antenna Doubler Installation

Textron Cessna 208B
34 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Caravan SERVICE BULLETIN
CAB-30-02
(107)Wait until the fluid sta rts to come out all the holes at t he sam e rat e along the full length of the
panel a nd increase the pressure to 65 p si.
(108)Continue the fluid purge until the panel i s correc tly purged in ac co rdanc e with Figure 3 and
Table 2.
NOTE: To get an even flow over the panel it may be necess ary to lightly run a dry cloth or
paper to wel over the leading edge a nd/ or t he dry spots of the panel during purging.
(109)Stop the fluid supply.
(110)Wa it until the fluid pressure is released.
(111) Disconnec t the purge tank lin es .
(112)Install a new S2800- 942 Sealing R ing and connect the left horizont al stabilizer TKS supply line
to the tailcone proportioning unit.
(113)Disconnect the right horizon tal st abil izer TKS panel supply line from t he tailcone proportioning
unit.
(114)Connect t he purge tank lines to th e right horizontal s tabilizer TKS panel as near to the panel as
you can.
(115)Apply pressure of 10 ps i, do a check for leaks in the line, and repa ir all leak s .
(116)Apply pressure of 20 psi to slowly start the flui d flow through the panel.
(117)Wait until the fluid sta rts to come out all the holes at the same rat e along the f ull length of the
panel a nd increase the pressure to 65 p si.
(118)Continue the uid purge until the panel is correctly purged in accordance w ith Figure 3 and
Table 2.
NOTE: To get an even flow over the panel it may be necess ary to lightly run a dry cloth or
paper to wel over the leading edge a nd/ or t he dry spots of the panel during purging.
(119)Stop the fluid supply.
(120)Wait until the fluid p ressure is released.
(121)Disconnect the purge tank lin es .
(122)Install a new S2 800-942 Sealing Ring and connec t the right horizontal stabilizer T KS supply
line to the tailcone proportioning unit.
(123)Disconnect the v ertica l stabilizer TKS panel supply li ne from the tailcone p ro portioning unit.
(124)Connect the vertical stabilizer TKS panel suppl y line directly to the purg e cart.
(125)Apply pressure of 10 ps i, do a check for leaks in t he line, and repair all leak s .
(126)Apply pressure of 20 psi to s lowly s tart the fluid flow through the panel.
(127)Wait until the fluid sta rts to come out all the holes at t he sam e rat e along the full length of the
panel a nd increase the pressure to 75 p si.
(128)Continue the fluid purge until the panel i s correc tly purged in ac co rdanc e with Figure 3 and
Table 2.
NOTE: To get an even flow over the panel it may be necess ary to lightly run a dry cloth or
paper to wel over the leading edge a nd/ or t he dry spots of the panel during purging.
(129)Stop the fluid supply.
(130)Wait until the fluid p ressure is released.
(131)Disconnect the purge tank lin es .
CAB-30-02