CESSNA SECTION 3
MODEL 208B 867 SHP EMERGENCY PROCEDURES
GARMIN G1000
U.S.
FAA APPROVED
SMOKE AND FIRE (Continued)
CABIN FIRE
WARNING
Without electrical power all electrically operated
flight and engine indications, fuel boost pump,
EIS annunciators, WING FLAPS Handle and all
navigation and communications systems will be
inoperative.
All standby instruments, including torque
indicator and vacuum-driven standby attitude
indicator, will be operative.
WARNING
Occupants should use oxygen masks (if installed)
until smoke clears. After discharging an
extinguisher within a closed cabin, ventilate the
cabin.
8. Land airplane as soon as possible to inspect for damage.
1. STBY ALT PWR Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . OFF
2. GENERATOR Switch. . . . . . . . . . . . . . . . . . . . . . . . . . . . TRIP
3. BATTERY Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . OFF
4. Vents . . . . . . . . . . . . . . . . . . . . . . . . CLOSED (to avoid drafts)
a. Forward Side Air VENT Knobs . . . . . . . CLOSE (push in)
b. Overhead Air Vents . . . . . . . . . . . . . . . . . . . . . . . . CLOSE
c. VENT AIR Control Knobs . . . . . . . . . . . . . . . . . . . CLOSE
d. AIR CONDITIONING Switch (if installed) . . . . . . . . . . OFF
5. TEMP Control Knob . . . . . . . . . . . . . . . . . . . . . . . . . . CLOSED
(rotate FULL counterclockwise)
6. BLEED AIR HEAT Switch . . . . . . . . . . . . . . . . . . . . . . . . . OFF
7. Fire Extinguisher . . . . . . . . . . . . . . . . . . . . . . . . . . . ACTIVATE
208BPHCUS-00 3-21