Loading...
SECTION 2 CESSNA
OPERATING LIMITATIONS MODEL 208B (867 SHP)
GARMIN G1000
U.S.
FAA APPROVED
MAXIMUM OPERATING ALTITUDE LIMIT
Non-Icing Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . 25,000 Feet
Icing Conditions (if equipped) . . . . . . . . . . . . . . . . . . . . 20,000 Feet
Any conditions with any ice on the airplane. . . . . . . . . . 20,000 Feet
OUTSIDE AIR TEMPERATURE LIMITS
Cold Day . . . . . . . . . . . . . . . . .-54°C from Sea Level to 25,000 Feet
Hot Day:
Ground Operations. . . . . . . . .+42°C from Sea Level to 5000 Feet
ISA +37°C above 5000 Feet
Flight Operations . . . . . ISA +37°C from Sea Level to 25,000 Feet
Refer to Section 5, Performance, Figure 5-5, ISA Conversion and
Operating Temperature Limits Chart, for a graphical presentation of the
operating air temperature limits.
NOTE
With both deck skin fans inoperative, ground operations
are limited to +42°C for 30 minutes.
Ground operations up to +38°C are not time limited with
both deck skin fans inoperative.
MAXIMUM PASSENGER SEATING LIMITS
In the passenger version, up to 11 seats may be installed. The right
front seat may be occupied by either a second crew member or a
passenger. When the right front seat is occupied by a passenger, only
eight seats in the aft cabin can be occupied.
In the cargo version, a maximum of one seat may be installed to the
right of the pilot’s seat for a second crew member or a passenger.
Refer to Section 6, Weight and Balance, Figure 6-11, Cabin Internal
Loading Arrangements, for approved seat locations.
208BPHCUS-00
2-28

Table of Contents