8.4.5 Drying mode
Indoor fan speed is fixed at breeze and can’t be
changed. The louver angle is the same as in
cooling mode.
All protections are active and the same as that
in cooling mode.
8.4.6 Forced operation function
Forced cooling mode:
The compressor and outdoor fan keep running
and the indoor fan runs at low speed. After
running for 30 minutes, AC will turn to auto
mode with 24 setting temperature.
Forced auto mode:
The action of forced auto mode is the same as
normal auto mode with 24 setting
temperature.
When AC receives signals, such as switch on,
switch off, timer on, timer off, mode setting, fan
speed setting, sleeping mode setting, follow me
setting, it will quit the forced operation.
8.4.7 Sleep function
8.4.7.1 The sleep function is available in
cooling, heating or auto mode.
8.4.7.2. Operation process in sleep mode is as
follow:
When cooling, the setting temperature rises 1
(be lower than 30) every one hour, 2 hours
later the setting temperature stops rising and
the indoor fan is fixed at low speed.
When heating, the setting temperature
decreases 1 (be higher than 17) every one
hour, 2 hours later the setting temperature
stops rising and indoor fan is fixed at low speed.
(Anti-cold wind function has the priority).
8.4.7.3 Operation time in sleep mode is 7 hours.
After 7 hours the AC quits this mode and turns
off.
8.4.7.4 Timer setting is available
8.4.8 Auto-Restart function
The indoor unit is equipped with auto-restart
function, which is carried out through an
auto-restart module. In case of a sudden power
failure, the module memorizes the setting
conditions before the power failure. The unit will
resume the previous operation setting (not
including swing function) automatically after 3
minutes when power returns.
If the memorization condition is forced cooling
mode, the unit will run in cooling mode for 30
minutes and turn to auto mode as 24 setting
temp.
If AC is off before power off and AC is required
to start up now, the compressor will have 1
minute delay when power on. Other conditions,
the compressor will have 3 minutes delay when
restarts.
8.4.9 Refrigerant Leakage Detection
With this new technology, the display area will
show “EC” when the outdoor unit detects
refrigerant leakage. This function is only
available in cooling mode.
8.4.10 Intelligent Light Detection
When room light is turned off, the display
window and V-shape light area will slowly
darken after 5s, and the buzzer turn off. It will
back to normal after the light is turned on.
NOTE: When the room light is dark, you can
press the LED button on the remote controller
to turn on/off the display window.
8.4.11 Smart Air Manager function
This mode can be chosen with SWING DIRECT
button on remote controller .And only available
under Cooling mode or Fan mode. The swing
act routinely in other modes.
The swing is controlled by natural wind Curve.
It will blow out very comfortable and quiet wind,
which brings you feeling of nature.
When the AC receives signals, such as switch
on, switch off or mode switch, it will exit this
function.
8.4.12 8
Heating(optional)
In heating operation, the preset temperature of
the air conditioner can be as lower as 8,